Notes: The first letter of the alarm code “ E ” (Error) is not displayed, since this letter is common to all alarm codes. The alarm code “families” are shown in hexadecimal; in other words: A is represented by 10 flashes B is represented by 11 flashes ... F is represented by 15 flashes Configuration errors are shown by the flashing of all the LEDs (user interface not configured). 5.2.2 Examples of alarm display Example: Alarm E43 (problems with the door interlock Triac) will display the following:

the sequence of four flashes of the START / PAUSE button with red light, indicates the first number E 4 3; the sequence of three flashes of the START / PAUSE button with green light, indicates the second number E4 3 ; 5.2.3 Operation of alarms during diagnostics All alarms are enabled during the components diagnostic phase. 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 12/59 599 70 32-47 START / PAUSE button with red light START / PAUSE button with green light ON/OFF On/Off (Ver. AEG) Time (Sec.) Value ON/OFF On/Off (Ver. AEG) Time (Sec.) Value 0.5 1 0.5 1 0.5 0.5 0.5 2 0.5 2 0.5 0.5 0.5 3 0.5 3 0.5 0.5 0.5 4 2.5 Pause 0.5 1.5 Pause