User Manual EM303B General Purpose Inverter Section 2 Advanced Parameters 8.8 F6 Group: Simple PLC Function 8.8.1 Options of Program Operation Mode and Time Unit 122 of F6-00. C0-21 Output Power Present output power kW C0-22 PID Input PID setting C0-23 PID Calculation Feedback PID feedback Torque Current Input Iq* Present torque current input setting value % C0-24 C0-25 Torque Current Feedback Iq Present output torque current value % Input Terminal Status X7 X6 X5 X4 X3 X2 X1 0 0 0 0 0 0 0 C0-26 X1 is the LSB. (Monitoring the logic status of external input terminals) Output Terminal Status * * * * R1 Y2 Y1 0 0 0 0 0 0 0 C0-27 Y1 is the LSB.

(Monitoring the logic status of output terminals) C0-28 VS Input Monitoring 0-10000 C0-29 IS Input Monitoring 0-10000 C0-30 VF Input Monitoring 0-10000 C0-31 IF Input Monitoring 0-10000 No. Function Range Unit Default Type Program Operation Mode Ones place: Options of programmable speed operation mode 0: Monocycle 1: Run as per Preset Speed 7 after monocycle 2: Limited times of continuous cycle 3: Continuous cycle Tens place: Not used Hundreds place: Not used Thousands place: Options of restart after operation paused 0: Restart from the section when it paused 1: Restart from Preset Speed 1 Ten thousands place: Program operation time unit 0: S 1:

min 00000 〇 F6-00 F6-15 Speed Cycling Times 1~10000 1 ●