User Manual EM303B General Purpose Inverter Thank you for purchasing EM303B series inverter. Document No.: 31010032 Version No.:104 Issue Date: 11/2015 EM303B is a general purpose vector control inverter. An induction motor with the help of EM303B canpossess fast speed response and torque control ability as a DC motor which makes the motion control system stable, precise,and quick. Main Features: 1. SVC (Sensorless vector control):Torque control accuracy: 5% rated torque. Speed Preface control accuracy: ±0.2% rated synchronous speed. 2. VVF (Vector decoupling based VF control): The steady performanceis the same as that in SVC. 3. Wide speed regulation range, load capacity at low frequency:
SVC/0.5Hz/150% rated load, VVF/1.0Hz/150% rated load. 4. Optimized current and voltage protection algorithm ensures that motor can accelerate/deceleratein 0.1S. 5. AVR function makes output voltage stable at grid voltage fluctuation. 6. Load disturbance compensation ensures failure-free operation of motor. 7. Auto-searching motor speed at restart smoothes thestart of motor without current over-shoot. 8. 2 acceleration/deceleration modes: linear and S curve. 9. The performance and stability are improved significantly with dual- CPU. It is the duty of any user to perform the appropriate, correct installation or configuration of the optional parameters of the devices.
Neither SINEE nor its distributors shall be responsible or liable for misuse of the information contained herein or mismatching the inverter with the motor. In the interests of commitment to a policy of continuous development and improvement, SINEE reserves the right to update the specification of the product or its performance, or the content herein without notice. More updates and information are available at www.sineedrive.com . 1
User Manual EM303B General Purpose Inverter Contents PREFACE ............................................................. 1 CONTENTS ............................................................ 2 SAFETY INFORMATION ................................................. 4 S AFETY P RECAUTIONS ..................................................... 4 1OVERVIEW ........................................................... 8 1.1 EM303B M ODEL L IST AND T ECHNICAL S PECIFICATIONS ......................... 8 1.2 D EFINITION OF EM303B O PERATION S TATUS ................................ 10 1.3 EM303B O UTLOOK ...................................................
13 2INSTALLATION ...................................................... 14 2.1 V ERIFYING P RODUCT .................................................. 14 2.2 O VERALL AND I NSTALLATION D IMENSIONS .................................. 15 2.3 C ONSIDERATIONS OF I NSTALLATION S ITE .................................... 17 2.4 D IRECTION AND S PACE OF I NSTALLATION ................................... 17 2.5 D ISASSEMBLY AND A SSEMBLY OF K EYPAD .................................. 19 2.6 F LUSH M OUNTING .................................................... 21 3WIRING .............................................................
22 3.1 C ONNECTIONS TO P ERIPHERALS .......................................... 22 3.2 W IRING M AIN C IRCUIT T ERMINALS ....................................... 23 3.3 W IRING C ONTROL C IRCUIT T ERMINALS .................................... 31 3.4 E XTENDING K EYPAD W IRE .............................................. 39 3.5 W IRING C HECK ....................................................... 40 4KEYPAD OPERATION ................................................. 41 4.1 T YPE AND F UNCTION OF K EYPAD ......................................... 41 4.2 LED K EYPAD O PERATION M ODE ......................................... 42 5TRIAL OPERATION ...................................................
49 5.1 T RIAL O PERATION P ROCEDURES .......................................... 49 5.2 T RIAL O PERATION P RECAUTIONS ......................................... 50 6PARAMETER TABLE .................................................. 52 6.1 F ORMAT OF P ARAMETER T ABLES .......................................... 52 6.2 P ARAMETER T ABLE .................................................... 52 S ECTION 1 G ENERAL P ARAMETERS ........................................... 52 S ECTION 2 A DVANCED P ARAMETERS .......................................... 66 7PARAMETER DESCRIPTION ........................................... 81 S ECTION 1 G ENERAL P ARAMETERS ...........................................
81 7.1 F0 G ROUP : G ENERAL P ARAMETERS ........................................ 81 7.2 F1 G ROUP : M OTOR P ARAMETERS ......................................... 92 7.3 F2 G ROUP : I NPUT / OUTPUT T ERMINAL P ARAMETERS ........................... 95 7.4 F3 G ROUP : P RESET S PEED O PERATION P ARAMETERS .......................... 105 7.5 F4 G ROUP : G ENERAL P ARAMETERS OF PID ................................. 110 7.6 F5 G ROUP : G ENERAL P ARAMETERS OF V ECTOR C ONTROL ...................... 116 7.7 C0 G ROUP : P ARAMETERS OF M ONITORING F UNCTION ......................... 121 2
User Manual EM303B General Purpose Inverter S ECTION 2 A DVANCED P ARAMETERS ......................................... 122 7.8 F6 G ROUP : S IMPLE PLC F UNCTION ....................................... 122 7.9 F7 G ROUP : A DVANCED P ARAMETERS OF O PERATION .......................... 128 7.10 F8 G ROUP : I NPUT /O UTPUT B IAS ........................................ 133 7.11 F9 G ROUP : S PEED S ETTING O PTIONS ..................................... 137 7.12 FA G ROUP : A DVANCED P ARAMETERS OF V ECTOR C ONTROL ................... 145 7.13 FC G ROUP : P ARAMETERS OF O PERATION C ONTROL .......................... 146 7.14 F D G ROUP : A UXILIARY P ARAMETERS ....................................
155 7.15 FE G ROUP : U SER D EFINED T ERMINAL F UNCTION P ARAMETERS ................ 158 8AUTOTUNING MOTOR PARAMETERS ................................. 162 8.1 A UTOTUNING M OTOR P ARAMETERS ...................................... 162 8.2 P RECAUTIONS B EFORE A UTOTUNING ..................................... 162 8.3 A UTOTUNING P ROCEDURE ............................................. 163 9TROUBLESHOOTING ................................................ 164 9.1 F AULTS ............................................................ 164 R EFERENCE OF LED C HARACTERS .......................................... 166 9.2 F AULT A NALYSIS .....................................................
167 10MAINTENANCE AND INSPECTION ................................... 170 10.1 M AINTENANCE AND I NSPECTION ........................................ 170 10.2 D AILY I NSPECTION .................................................. 170 10.3 P ERIODIC M AINTENANCE ............................................. 170 10.4 P ERIODIC M AINTENANCE AND R EPLACEMENT OF P ARTS ...................... 171 10.5 O UTLINE OF W ARRANTY .............................................. 171 11ACCESSORIES ..................................................... 172 11.1 K EYPAD E XTENSION W IRE ............................................ 172 11.2 R EMOTE C ONTROL C ASE ..............................................
172 11.3 B RAKING R ESISTOR ................................................. 173 11.4 B RAKING U NIT ..................................................... 174 11.5 C ONNECTING C ABLE ................................................. 174 11.6 C HASSIS FOR F LOOR M OUNTING ........................................ 174 11.7 E XTENDED C OPPER B AR .............................................. 176 12MODBUS COMMUNICATION PROTOCOL .............................. 177 12.1 A PPLICATION S COPE ................................................. 177 12.2 P HYSICAL I NTERFACE ................................................ 177 12.3 P ROTOCOL F ORMAT .................................................
177 12.4 E XPLANATION OF C OMMAND .......................................... 177 12.5 D ESCRIPTION OF P ROTOCOL F ORMAT .................................... 179 12.6 D ESCRIPTION OF C ONTROL C OMMAND ................................... 182 12.7 E XAMPLE ......................................................... 183 12.8 T ROUBLESHOOTING OF COMMON COMMUNICATION .......................... 184 3
User Manual EM303B General Purpose Inverter Safety Information Danger: The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed. Caution: This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or a risk of damage to the products or other devices. Safety Precautions Before Installation Danger 1. Do not install the product if the package is with water, or component is missing or broken. 2.
Do not install the product if the label on the package is not identical to that on the inverter. Danger 1. Be careful of carrying or transportation. Risk of devices damage. 2. Do not use damaged product or the inverters missing component. Risk of injury. 3. Do not touch the parts of control system with bare hands. Risk of ESD hazard. Installation: Danger 1. Installation base shall be metal or other non-flammable material. Risk of fire. 2. Do not unscrew the fixing bolts, especially the bolts with red mark. Caution 1. Do not leave cable strips or screws in the inverter. Risk of inverter damage. 2. Install the product at the place with less vibration and no direct sunlight. 3.
Consider the installation space for cooling purpose when the inverter is installed in a cabinet. 4