sinee — EM303B User Manual (EN)

User Manual EM303B General Purpose Inverter 6.2.6 F5 Group: General Parameters of Vector Control 62 No. Function Range Unit Default Type S/N F5-00 Speed Proportional Gain ASR P1 _ 0.00~100.00 % 15.00 ● 160 Speed Integral Time ASR Ti1 _ 0.00~30.00 0.00: No integration S 0.50 ● 161 F5-01 F5-02 Speed Differential Time ASR Td1 _ 0.00~10.00 mS 0.00 ● 162 F5-03 Speed Proportional Gain ASR P2 _ 0.00~100.00 % 12.00 ● 163 Speed IntegralTime ASR Ti2 _ 0.00~30.00 0.00:

No integration S 0.50 ● 164 F5-04 F5-05 Switching Frequency 0 0.00~Switching Frequency 1 Hz 5.00 〇 165 F5-06 Switching Frequency 1 Switching Frequency 0~Fmax Hz 10.00 〇 166 F5-07 Torque Current Acceleration Time 0.000~30.000 S 0.040 ● 167 F5-08 Torque Current Deceleration Time 0.000~30.000 S 0.040 ● 178 F5-09 Power Torque Current Limit 80.00~250.00 % 165.00 ● 169 F5-10 Brake Torque Current Limit 80.00~250.00 % 165.00 ● 170 Regular Torque Setting 0: Primary Numeric Torque Setting 1: VP 2: VS 3: IS 4: VF 5: IF 6: Not used 7: K1*VP+K2*(K3*VS+ K4*IS+K5*VF+K6*IF-K8*5V ) 0 〇 171 F5-11 F5-12 Primary Numeric Torque Current 0.00~Maximum torque % 0.00 ● 172 Torque Direction 0: Positive Torque 1:

Negative Torque 0 ● 173 F5-13 Upper Limit Frequency Limiting of Torque 0: Upper Limit Frequency 1: VS* Upper Limit Frequency 2: IS*Upper Limit Frequency 3: VF*Upper Limit Frequency 4: IF*Upper Limit Frequency 0 〇 174 F5-14 Static friction compensation coefficient 0.00~150.00 % 0 ● 175 F5-15 F5-16 Not Used 176 Static friction acting cut-off frequency 0.00~50.00 Hz 2.00 〇 177 F5-17 F5-18 Not Used 178 ~179 ~F5-19 F5-20 Gain of VVF Excitation Current 0~60000 0 ● 180