sinee — EM303B User Manual (EN)

User Manual EM303B General Purpose Inverter Section 2 Advanced Parameters 7.1.2 F6 Group:Simple PLC Function 66 UL:Overvoltage stall Cl:Overcurrent stall E0-23 Working Time at Fault HOUR 0 × 567 E0-24 The 3rd Most Recent Fault Fault trips 0 × 568 E0-25 Output Frequency at Fault XX.XX/XX.X Hz 0.00 × 569 E0-26 Output Current at Fault XXX.X A 0.0 × 570 No. Function Range Unit Default Type S/N E0-27 DC Bus Voltage at Fault XXXX V 0.0 × 571 E0-28 Running Direction at Fault For:Forward rEu: Reverse 0 × 572 Running Status at Fault ACC: Acceleration COn: Constant Speed dEC: Deceleration 0 × 573 E0-29 Stall Status at Fault 0: Normal Ul: Overvoltage stall Cl:

Overcurrent stall 0 × 574 E0-30 Working Time at Fault HOU R 0 × 575 E0-31 No. Function Range Unit Default Type S/N Program Operation Mode Ones place: Options of programmable speed operation mode 0: Monocycle 1: Run as per Preset Speed 7 after monocycle 2: Limited times of continuous cycle 3: Continuous cycle Tens place: Not used Hundreds place: Not used Thousands place: Options of restart after operation paused 0: Restart from the section when it paused 1: Restart from Preset Speed 1 Ten thousands place: Program operation time unit 0: S 1: min 00000 〇 192 F6-00 Preset Program Operation Section 1 Ones place: Motor running direction options 0: Forward1: Reverse Tens place:

Options of acceleration /deceleration time 0: Acceleration / Deceleration time 1 1: Acceleration / Deceleration time 2 2: Acceleration / Deceleration time 3 3: Acceleration / Deceleration time 4 100 〇 193 F6-01