EM500 Open-Loop Vector Control Inverter User Manual 124 Synchronous Motor F14.62 MTPA Control Options of Synchronous Motor 0: Disabled 1:
Enabled 0 〇 F14.63 Gain of Autotuning at Initial Position 0 - 600 % 80 ● F14.64 Frequency of Injection Current at Low Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 10.00 ● F14.65 Injection Current at Low Frequency Range 0.0 - 60.0 (100.0= Motor Rated Current) % 20.0 ● F14.66 Low Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F14.67 Integral Time of Low Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ● F14.68 Frequency of Injection Current at High Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 20.00 ● F14.69 Injection Current at High Frequency Range 0.0 - 30.0 (100.0= Motor Rated Current) % 8.0 ● F14.70 High Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F14.71 Integral Time of High Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ● F14.72 - F14.73 Not Used F14.74 Angle 0.0 - 30.0 ° 0.0 ●