EM500 Open-Loop Vector Control Inverter User Manual 125 Compensation Phase of Synchronous Motor F14.75 Angle Compensation Gain of Synchronous Motor 0.00 - 300.00 % 0.00 ● F14.76 Angle Compensation Filter Time of Synchronous Motor 0.000 - 30.000 s 0.100 ● F14.77 Motor 2 Acceleration/Decele ration Time 0: Same as Motor 1 1: Acceleration/Deceleration Time 1 2: Acceleration/Deceleration Time 2 3: Acceleration/Deceleration Time 3 4: Acceleration/Deceleration Time 4 0 〇 F14.78 Motor 2 Maximum Frequency 1.00~600.00 Hz 50 ● F14.79 Motor 2 Upper Limit Frequency Lower Limit Frequency F00.19 ~ Maximum Frequency F14.78 Hz 50 ● F14.80 Motor 2 V/F Curve Setting 0: Straight Line V/F 1:

Multi-Dot Polyline V/F 0 ● F14.81 Motor 2 Multipoint VF Frequency Point F1 0.00~F14.83 Hz 0.50 ● F14.82 Motor 2 Multipoint VF Voltage Point F1 0.0~100.0(100.0 = rated voltage) % 1.0 ● F14.83 Motor 2 Multipoint VF Frequency Point F2 F14.81~F14.85 Hz 2.00 ● F14.84 Motor 2 Multipoint VF Voltage Point F2 0.0~100.0 % 4.0 ● F14.85 Motor 2 Multipoint VF Frequency Point F3 F14.83~motor rated frequency(reference frequency) Hz 5.00 ● F14.86 Motor 2 Multipoint VF Voltage Point F3 0.0~100.0 % 10.0 ● F14.87 Stop Mode 0: Ramp-To-Stop 1: Coast-to-Stop 0 ●