EM500 Open-Loop Vector Control Inverter User Manual 148 F28.49 Air filter using time presets 0~9000 h 4500 ● F28.50 Lubricating oil using time presets 0~9000 h 4500 ● F28.51 Grease using time presets 0~9000 h 4500 ● F28.52 Preset alarm delay time 0~100 h 10 ● F28.53 The Power meter timing reset 0: No Used 1: Reset 0 ● F28.54 Inching loading delay 0~60 s 3 〇 F28.55 Protection block First place: mechanical maintenance time up protection Second place: Pressure overrun protection Third place: Pressure feedback disconnection protection Fourth place: Temperature overrun protection Fifth place: Temperature feedback disconnection protection Sixth place: Not Used Seventh place:
The motor feedback disconnection protection Eighth place: Not Used From right to left (0- No shield 1-shield ) 0000 0001 〇 F28.56 ~ F28.65 Not Used F28.66 JZ Multi-function set See the output terminals function table 49 〇 F28.67 BJ Multi-function set See the output terminals function table 7 〇 F28.68 Interface card Positive and negative logic setting 0: JT Normally closed 1: JT Normally open 0 〇 F28.69 Sensor offset curve setting Ones Place: Interface board oil temperature 120 〇