sinee — 6.2 Function Parameter Table

EM500 Open-Loop Vector Control Inverter User Manual 149 0: Curve 1 1: Curve 2 2: Curve 3 3: Curve 4 Tens Place: Interface board Motor temperature 0: Curve 1 1: Curve 2 2: Curve 3 3: Curve 4 hundreds place: Interface board pressure 0: Curve 1 1: Curve 2 2: Curve 3 3: Curve 4 F28.70 Add and subtract load state 0: Unloading state 1: Loading state 2: Dormant state 0 × F28.71 Time Error query First place: Oil filter time Second place: Oil separator time Third place: Air filter time Fourth place: Lubricating oil time Fifth place:

Grease time From right to left 00000 × F28.72 Stop delay remaining time 0~60000 s XXX × F28.73 Continuous no-load running time 0~60000 s XXX × F28.74 Stop and restart remaining time 0~60000 s XXX × F28.75 The electricity meter: MWh 0~65535 Mw h XXX × F28.76 The electricity meter: KWh 0~65535 KW h XXX × F28.77 The Running Time 0~60000 h XXX × F28.78 Pressure feedback 0.00~600.00 MPa 0 × F28.79 oil passage temperature feedback 0.0~200.0 ℃ 0 × F28.80 Motor temperature 0.0~200.0 ℃ 0 ×