sinee — 4.2 LED Keypad Operation Mode

EM600 High-Performance Vector Control Inverter User Manual 4.2 LED Keypad Operation Mode 4 menu levels of LED keypad: monitoring (level 0), menu mode selection (level 1), function code selection (second level) and parameter value (third level). In the following parts, menu levels are represented by figures. 3 parameter display modes: all menu mode (--A--) displays all function codes; user-defined mode (--U--), only displays function parameters selected by user through F11 group; non-factory defaults (--C--), only displays those function codes that are different from the factory setting.

When keypad is powered, default display is the first monitoring parameter of level 0; press ESC to enter menu level 1, from which using and to select a menu mode. Operation procedure for menu mode selection is shown in Figure 4–2. 47 Button/Indicator Name Function Up Select function code, menu group or increase set parameter value. Increase numeric input data of present effective reference. Down Select function parameter, menu group or decrease set parameter value. Decrease numeric input data of present effective reference. LED Display function setting, running monitoring, fault monitoring code and parameter. Frequency Indicator On when present parameter is frequency.

Current Indicator On when present parameter is current. Voltage Indicator On when present parameter is voltage. Percentage Indicator On when present parameter is percentage. Forward/Reverse Indicator On at the time of monitoring or displaying some special frequency as negative. On when reversing Communication Control Indicator On when F00.02 is set to keypad control, off when F00.02 is set to terminal control, flickers when F00.02 is set to communication control. Status Indicator On when inverter is running, flickers when stopping, off after stop. Fault Indicator On when inverter is in fault state.