User Guide of EM730 Series Inverter discontinuous status, please select appropriate wires. See Chapter 3 for the wiring specifications of the main circuit. Use the cables with the conforming insulation levels and cross-sections. Flexible cables have higher flexibility. Because cables may be in contact with high-temperature devices, it is recommended to use copper-core and heat-resistant flexible cables or flame-retardant cables. The braking unit should be close to the inverter as much as possible and no more than 2m far away from the inverter. Otherwise, the DC-side cables should be twisted and used with magnetic rings to reduce radiation and inductance.
6.3 Wi-Fi module Applicable Wi-Fi module and model for EM730 series inverters: EM730-WIFI. The inverter can be controlled by the mobile phone APP, PC background software and the like for quick parameter setting, parameter copying and status monitoring of the inverter. Installation of the Wi-Fi module: First unplug the keyboard from the inverter and then install the Wi-Fi module to the original keyboard position. The external schematic diagram of the Wi-Fi module is as follows. 59 Specification Average Braking Peak Braking Current Cross-section (mm2) of and model Current I (A) av I (A) max Copper-core Cable BR100-045 45 75 10 BR100-160 75 150 16 BR100-315 120 300 25