User Manual of EM730/EM730E Series Inverter The EM730/EM730E series inverter supports time-sharing control of two motors. The motor parameters and control parameters can be set separately. The corresponding parameters of the motor 1 are in the F00 group, F01 group and F06 group, and those of the motor 2 are in the F14 group. The valid motor can be selected in conjunction with F00.28 and the input function “Motor 1/Motor 2 switching”, as detailed in Table 7-5. Table 7-5 Details of Motor Parameter Group Options F00.29 is used to set a password to enable the password protection and prevent the function code parameters of the inverter from modification by unauthorized personnel.
If the password is set to 0, the password function will be invalid. When a non-zero user password is set, all parameters (except this function code) can only be viewed and are not modifiable. The maximum frequency in this mode is 600.00Hz. F00.31=0: The frequency resolution is 0.01Hz, corresponding to the frequency of 50.00Hz. F00.31=1: The frequency resolution is 0.1Hz, corresponding to the frequency of 50.00Hz. The maximum frequency in this mode is 3000.0Hz. It is suitable for high-frequency spindle motors. 146 parameter group 1 1: parameter group of motor 2 F00.28: Motor parameter Related parameter 30: motor 1/motor 2 switching Valid motor group options group 0:
parameter group of motor 1 Invalid Motor 1 F00/F01/F06 Valid Motor 2 F14 1: parameter group of motor 2 Invalid Motor 2 Valid Motor 1 F00/F01/F06 Function code Default Function code Parameter description Unit Attribute name setting F00.29 User password 0 - 65535 0 〇 Function code Default Function code Parameter description Unit Attribute name setting F00.31 Frequency resolution 0:0.01Hz 1: 0.1Hz (speed unit: 10rpm) 0 〇