sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter F00.55=0: 380V The voltage of the applied power supply is 380V. F00.55=1: 440V the corresponding dynamic braking voltage and stall overvoltage will increase accordingly. The voltage of the applied power supply is 440V. When the function code is set to 440V, 7.2 Motor 1 parameter group of F01 group The EM730/EM730E series inverter supports asynchronous and synchronous motors. Please set this parameter correctly according to the actual situation. 147 Default t setting Function code Function code name Parameter description Uni Attribute F00.35 Power supply voltage selection 0: 380V 1:

440V 0 〇 Function Unit Default Function code name Parameter description Attribute code setting F01.00 Motor type 0: ordinary asynchronous motor 1: variable-frequency asynchronous motor 2: permanent magnet synchronous motor 0 〇 Function Function code Default Parameter description Unit Attribute code name setting F01.01 Rated power of electric motor 0.10~650.00 kW Depending on the motor type 〇 F01.02 Rated voltage of motor 50~2000 V Depending on the motor type 〇 F01.03 Rated current of motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.1 to 6000.0 (rated power of motor:

> 75 kW) A Depending on the motor type 〇 F01.04 Rated frequency of motor 0.01~600.00 Hz Depending on the motor type 〇 F01.05 Rated speed 1~60000 rpm Depending 〇