User Manual of EM730/EM730E Series Inverter the motor is connected to the inverter for the first time, regardless of VF control or vector The above function codes are the nameplate parameters of the asynchronous motor. When control, the above parameters must be correctly set according to the motor nameplate before operation. the inverter will change automatically. Pay attention to this during operation.

When the rated power (F01.01) of the motor is changed, the values of F01.03 to F01.08 of 148 on the motor type F01.06 Motor winding connection 0:Y 1:Δ Depending on the motor type 〇 F01.07 Rated power factor of motor 0.600~1.000 Depending on the motor type 〇 F01.08 Motor efficiency 30.0~100.0 % Depending on the motor type 〇 Function Function code Default Parameter description Unit Attribute code name setting F01.09 Stator resistance of asynchronous motor 1-60000 (rated power of motor: ≤ 75 kW) 0.1-6000.0 (rated power of motor: > 75kW) mΩ Depending on the motor type 〇 F01.10 Rotor resistance of asynchronous motor 1-60000 (rated power of motor: ≤ 75 kW) 0.1-6000.0 (rated power of motor:

> 75kW) mΩ Depending on the motor type 〇 F01.11 Leakage inductance of asynchronous motor 0.01 to 600.00 (rated power of motor: ≤ 75 kW) 0.001 to 60.000 (rated power of motor: > 75 kW) mH Depending on the motor type 〇 F01.12 Mutual inductance of asynchronous motor 0.1 to 6000.0 (rated power of motor: ≤ 75 kW) 0.01 to 600.00 (rated power of motor: > 75 kW) mH Depending on the motor type 〇