User Manual of EM730/EM730E Series Inverter Precautions for setting: ★ The start and stop in multi-segment speed operation depends on the function code F00.02. ★ The acceleration/deceleration time in multi-segment speed operation can be controlled by the external terminal with the acceleration/deceleration time function. The direction of multi-segment speed operation is controlled by the terminals F/R and RUN. In addition to the multi-segment speed mode, it also has the simple PLC function.

There are 209 speed 6 8 Invalid Valid Valid Valid Multi-segment speed 7 F08.06 9 Valid Invalid Invalid Invalid Multi-segment speed 8 F08.07 10 Valid Invalid Invalid Valid Multi-segment speed 9 F08.08 11 Valid Invalid Valid Invalid Multi- speed 10 F08.09 12 Valid Invalid Valid Valid Multi-segment speed 11 F08.10 13 Valid Valid Invalid Invalid Multi-segment speed 12 F08.11 14 Valid Valid Invalid Valid Multi-segment speed 13 F08.12 15 Valid Valid Valid Invalid Multi-segment speed 14 F08.13 16 Valid Valid Valid Valid Multi-segment speed 15 F08.14 Function code Function code name Default Parameter description Unit Attribute setting F08.15 Simple PLC running mode 0: stop after a single run 1:

stop after a limited number of cycles 2: run at the last segment after a limited number of cycles 3: continuous cycles 0 ● F08.16 Limited number of cycles 1 - 10000 1 ●