sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter Flicker bit Flicker bit Fig. 4-5 Function Code Modification in Non-default Mode Flicker bit Flicker bit 4.2.4 Protection information display mode ( -- E -- ) In the protection information display mode, press the ENTER key to enter the Level 2 menu. The Level 2 menu will only display the fault record group under the F19 group, which is conducive to direct viewing of protection record information. on the keyboard in the Level 2 menu under this mode to increase or decrease the function code of the protection group, and the shift key will be unavailable.

In case of protection, you can press the shift key Turn the potentiometer key on the keyboard in the Level 3 menu to switch the display of the protection code, protection output frequency, protection output current, protection bus voltage, and protection operation status. 4.3 Protection Monitoring When the inverter is in the protection status, you can directly press the right shift key to switch the current protection type and the output frequency, output current, output voltage, running status and working time during the protection. 4.4 Operation Monitoring 4.4.1 Normal monitoring viewed between F12.33 and F12.37. When F12.32=1, the monitoring mode 1 will be enabled.

If the Level 0 monitoring menu appears, you can press the right shift key In the monitoring status mode 1 of EM730/EM730E, you can set any function code to be to switch the monitoring parameters according to the order set for each function code between F12.33 and F12.37. When the inverter changes from the stop status to running status, the monitoring 54