sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter 82 output F06.08 Vector control slip gain 50.00-200.00 % 100.00 ● F06.09 Upper limit source selection of speed control torque 0: set by F06.10 and F06.11 1: AI1 2: AI2 3: retention 4: retention 5: Communication setting (percentage) 6: the larger of AI1 and AI2 7: The smaller of AI1 and AI2 0 〇 F06.10 Upper limit of speed control motor torque 0.0 - 250.0 % 165.0 ● F06.11 Upper limit of speed control brake torque 0.0 - 250.0 % 165.0 ● F06.12 Excitation current proportional gain ACR-P1 0.00-100.00 0.50 ● F06.13 Excitation current integral time constant ACR-T1 0.00-600.00 0.00: