sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter 83 cy processing 2: seal the tube F06.18 SVC zero-frequen cy braking current 50.0-400.0 (100.0 is the no-load current of the motor) % 100.0 〇 F06.20 Voltage feedforward gain 0 - 100 % 0 ● F06.21 Flux weakening control options 0: Invalid 1: direct calculation 2: automatic adjustment 2 〇 F06.22 Flux weakening voltage 70.00-100.00 % 95.00 ● F06.23 Maximum field weakening current of synchronous motor 0.0-150.0 (100.0 is the rated current of the motor) % 100.0 ● F06.24 Proportional gain of flux weakening regulator 0.00 - 10.00 0.50 ● F06.25 Integral time of flux weakening regulator 0.01 - 60.00 s 2.00 ● F06.26 MTPA control option of synchronous motor 0:

Invalid 1: valid 1 〇 F06.27 Self-learning gain at initial position 0 - 200 % 100 ● F06.28 Frequency of low frequency band of injection current 0.00-100.00 (100.00 is the rated frequency of the motor) % 10.00 ●