24 Function Command Epson Web Control Setting Availability Setting Value/Response Value Quick Corner Coordinate Settings/Acquire settings QC x1 x2 x3 x4 x5 x6 x7 x8 ü - Parameter x1-x8: -4999 to 5000 Specify in the order: top left (x, y), top right (x,y), bottom right (x, y), bottom left (x, y) QC? ü - Return code -4999 to 5000 Coordinates (x, y) for 4 points are divided into 4 lines and responded Quick Corner Vector Settings QCV x1 x2 x3 x4 x5 x6 x7 x8 ü - Parameter x1-x8: -99 to 99 Specify in the order: top left (x, y), top right (x,y), bottom right (x, y), bottom left (x, y) Quick Corner Coordinate Shift QCMV control direction movement ü - Parameter control:
QC control location specifications 01: Top left control 02: Top right control 03: Bottom right control 04: Bottom left control INIT (settings only) direction: Direction specifications 01: Move up 02: Move down 03: Move left 04: Move right movement: Amount of movement specifications Only INC is enabled (settings only) Keystone/screen correction method settings/acquisition CORRECTMET x1 ü - CORRECTMET? ü - Parameter/Return code 00: Off 01: H/V-Keystone 02: Quick Corner correction 03: Point Correction 04: Curved Surface Correction 05: Corner Wall Correction Geometry Correction Load Memory POPGC x1 ü - Parameter 01: Memory 1 02: Memory 2 03:
Memory 3 Geometry Correction Save Memory PUSHGC x1 ü - Parameter 01: Memory 1 02: Memory 2 03: Memory 3 Geometry Correction Erase Memory ERASEGC x1 ü - Parameter 00: ALL (Geometry Correction Reset Memory Settings) 01: Memory 1 02: Memory 2 03: Memory 3 Geometry Correction Rename/Acquire Memory NAMEGC x1 x2 ü - Parameter x1 Memory No. 01: Memory 1 02: Memory 2 03: Memory 3 x2 Custom name (ASCII code) NAMEGC? x1 ü - Parameter Same as first parameter for NAMEGC Return code Same as second parameter for NAMEGC