25 Function Command Epson Web Control Setting Availability Setting Value/Response Value Aspect settings/Acquire settings ASPECT x1 ü - ASPECT? ü - Parameter/Return code When screen type is set to 4:3 10: 4:3 20: 16:9 30: Auto 50: H-Zoom 60: Native A0: V-Zoom INIT (settings only) When screen type is set to 16:9 30: Auto 40: Full 50: H-Zoom 60: Native A0: V-Zoom INIT (settings only) When screen type is set to 16:10 20: 16:9 30: Auto 40: Full 50: H-Zoom 60: Native A0: V-Zoom INIT (settings only) When screen type is set to 16:6 30: Auto 40: Full INIT (settings only) When selected (acquire only) x1: Mode x2:
Auto parameters (fixed at 30) Screen Type Settings/Acquire settings SCFORMAT mode param ü - SCFORMAT? mode ü - Parameter/Return code mode: Settings Mode 01: Screen Type Settings 02: Screen Position Settings INIT (settings only) param: Value (mode = 01) 01: 4:3 02: 16:9 03: 16:10 04: 16:6 05: 21:9 param: Value (mode = 02) C19 to 000 to 3E7 Brightness Control/Light Source Mode Settings/Acquire settings LUMINANCE x1 ü - LUMINANCE? ü - Parameter/Return code 00: Normal 01: Quiet 04: Extended 05: Custom INIT (settings only) Brightness Level Settings/ Acquire settings LUMLEVEL level ü - LUMLEVEL?
ü - Parameter/Return code 0-255 INIT/INC/DEC (settings only) (Brightness) Set/Acquire Constant Brightness LUMCONST x1 ü - LUMCONST? ü - Parameter/Return code 00: Off 01: On