EPSON — ^BA

^BA [Name] Code 93 barcode [Format] ^BA o ,h ,i ,a ,c [Function]  Sets Code 93 barcode to the field.  Sets the field orientation based on Parameter o.  Sets the barcode height based on Parameter h.  Sets the HRI character printing based on Parameter i.  Sets whether to position the added HRI characters on the top or on the bottom of the barcode based on Parameter a.  Sets the check digit printing based on Parameter c. [Encoding]  Numerals (0 to 9), capital letters of the alphabet (A to Z), hyphens , periods , dollar symbols , slashes , plus symbols , percent symbols , and blank spaces can be encoded.

 If the width of the barcode to be rendered exceeds the label width, only the part that fits in the label width will be printed.  The check digit is added automatically. The check digit is calculated by modulus 47.  The start and stop codes are printed as squares for HRI characters.  All ASCII code (128 types) can be specified in the field data using a combination of shift codes and characters. ESC/Label Command Reference Guide Rev. L Page 61 Parameters Description Definition range o Code 93 field orientation o = N/R/I/B N: Normal R: 90° rotation (clockwise) I: 180° rotation B:

270° rotation (clockwise) h Code 93 barcode height [dot] 1 ≤ h ≤ 32000 (Varies depending on the model) i Set/cancel of HRI character addition for Code 93 i = Y/N Y: Set N: Cancel a Set/cancel of HRI character addition for top of Code 93 barcode a = Y/N Y: Set N: Cancel c Set/cancel check digit printing for Code 93 c = Y/N Y: Set N: Cancel