omron — CONFIG real-valued function

CONFIG real-valued function When the select parameter is 6, 7, or 8, the CONFIG function returns a value that represents the setting of the FINE tolerance. When the select parameter is 9, 10, or 11, the CONFIG function returns a value that represents the setting of the COARSE tolerance.

eV+Language Reference Guide, v2.x, 18319-000 Rev A Page 132 Bi- t# Bit Mas- k Indicatio- n if bit CLEAR Bit SET 1 1 (None) (None) 2 2 FINE asserted COARSE asserted 3 4 NULL asserted NONULL asserted 4 8 MULTIPLE asserted SINGLE asserted 5 ^H1- 0 CPON asserted CPOFF asserted 6 ^H2- 0 OVERLAP asserted NOOVERLA- P asserted Select FINE tolerance returned 6 The permanent setting, as a percentage of the standard tolerance. 7 The setting used for the previous or current motion, as a percentage of the standard tolerance. 8 The setting to be used for the next motion, as a percentage of the standard tolerance.