omron — 7.3.3. fhrunsendcmd

*1: “SP” is space *2: The command argument n depends on the number of non-procedural command arguments.  Return Value The length of the string of the no-stepping command that can be sent is 127 bytes (not  Precautions including the delimiter). Set the input parameters so that the string length of the no-procedure command does not exceed 127 bytes.  Example In the following example, we will switch to scene number 5. Number of arguments of the no- procedure command No-procedure command name No-procedure command argument 1 46 Err. No.

Error Message Description 0 - normal termination -1506 ERROR:fhrunsendcmd():Invalid Command Argument No.:-1506 The number of non- procedural command arguments is out of the input range. -1601 ERROR:fhsendstring():NO CONNECT:-1601 _ Unconnected state -1601 ERROR:fhsendstring():NO DATA:-1601 _ Send string length 0 -1602 ERROR:fhsendstring():STRING LEN:-1602 _ Send string length over