omron — 7.3.3. fhrunsendcmd

7.3.3. fhrunsendcmd  Function Send a no-procedure command to the Vision Sensor  Input Parameters  Output Parameters None  Exit Process There are two exit nodes in this component as follows NoError : Normal termination. Error :

Abnormal termination (Please check the message displayed in the view window.)  Remarks 45 Setting Node Setting Target Data Description Type SendString ChooseDevice device Communication Settings for the Vision Sensors WaitTime int Communication waiting time(ms) inputArgument cmdArgNum int Number of no-procedural command arguments to be sent to the Vision Sensor (0 to 5) cmdName String No-procedural commands to be sent to the Vision Sensor cmdArg[0] String Argument 1 of the no-procedure command sent to the Vision Sensor(string). cmdArg[1] String Argument 2 of the no-procedure command sent to the Vision Sensor(string).

cmdArg[2] String Argument 3 of the no-procedure command sent to the Vision Sensor(string). cmdArg[3] String Argument 4 of the no-procedure command sent to the Vision Sensor(string). cmdArg[4] String Argument 5 of the no-procedure command sent to the Vision Sensor(string). Sends a no-procedure command to the Vision Sensor, concatenating the parameters according to the following format. If the number of no-protocol command arguments is out of the input range, an error is returned. No-protocol command SP(*1) Command argument 1 SP Command argument 1 SP … Command argument n(*2)