3.1.1. Setting Communications for Robot Controller Please follow the procedures below to set the communications for the robot controller. 17 Press [MENU] on the teaching pendant to display the right figure (HOME1 window). Select [Next>] - [Maint] - [Info] and then refer to the IP address for the robot controller on the SYSTEM INFORMATION window. 1 Connect the PC and the robot controller with LAN cables. 2 With right-click, select [Network and Sharing Center] - [Change adapter settings] from the control panel of the PC and open the property for a network adapter connecting the robot controller.
The dialog shown on the right will be displayed, select [Internet protocol version 4 (TCP/IPv4)] and open the property. 3