HP — Tray Adjustment Procedure

Note See figure 4-2. Each adjustment notch changes the physical position of the tray by 0.5 mm (0.02 inch). Moving the lever counter-clockwise moves the tray inward and increases distance A. Moving the lever clockwise moves the tray outward and decreases distance A. Figure 4-2 Tray Position Adjustment 1 If distance A is greater than distance B by more than 0.5 mm (0.02 inch), move the adjustment lever clockwise one notch. 2 If distance A is less than distance B by more than 0.5 mm (0.02 inch), move the adjustment lever counter-clockwise one notch. 3 After adjusting: • Reinstall the tray. • Re-run the Paper Path Test. • Recheck the measurements. • Re-adjust as necessary.

C4085-91087 Tray Adjustment Procedure 87