omron — Руководство по эксплуатации Omron Controller G70V/G7TC/G70A/G70D/G70R (EN)

Table of I/O Relay Terminal and connectable device combinations G70D/G70R Combinations with the OMRON PLC CS Series Note: We are scheduled to stop accepting orders for the G70R-SOC08 in March 2019. *1. The box @ is replaced by the cable length. For type details, refer to the XW2Z-R data sheet. (Cat. No. G126) *2. 8 outputs type.

21 CS1W I/O Units Conne ction pattern XW2Z-R Cables G70D/G70R Relay Terminals I/O capacity Model External connectors Polarity Connection Model *1 Quantity required Specifications Model Quantity required Output Units Transistor Output Units 32 outputs CS1W-OD231 1 Fujitsu connector (40p) Sinking (NPN) A 1:2 XW2Z-RO@C-@ 1 NPN outputs G70D-SOC16/FOM16 2 1:2 XW2Z-RO@C-@ 1 NPN outputs G70D-VSOC16/VFOM16 2 1:2 XW2Z-RO@C-@ 1 NPN outputs G70D-SOC08 *2 2 1:2 XW2Z-RO@C-@ 1 NPN outputs G70R-SOC08 *2 2 CS1W-OD232 1 Fujitsu connector (40p) Sourcing (PNP) 1:2 XW2Z-RO@C-@ 1 PNP outputs G70D-SOC16-1/FOM16-1 2 64 outputs CS1W-OD261 2 Fujitsu connectors (40p) (2, 32-point connectors) Sinking (NPN) B 1:2 XW2Z-RO@C-@ 2 NPN outputs G70D-SOC16/FOM16 4 1:2 XW2Z-RO@C-@ 2 NPN outputs G70D-VSOC16/VFOM16 4 1:2 XW2Z-RO@C-@ 2 NPN outputs G70D-SOC08 *2 4 1:2 XW2Z-RO@C-@ 2 NPN outputs G70R-SOC08 *2 4 CS1W-OD262 2 Fujitsu connectors (40p) (2, 32-point connectors) Sourcing (PNP) 1:2 XW2Z-RO@C-@ 2 PNP outputs G70D-SOC16-1/FOM16-1 4 96 outputs CS1W-OD291 2 Fujitsu connectors (56p) (2, 48-point connectors) Sinking (NPN) D 1:3 XW2Z-R@C-@-@ 2 NPN outputs G70D-SOC16/FOM16 6 1:3 XW2Z-R@C-@-@ 2 NPN outputs G70D-VSOC16/VFOM16 6 1:3 XW2Z-R@C-@-@ 2 NPN outputs G70D-SOC08 *2 6 1:3 XW2Z-R@C-@-@ 2 NPN outputs G70R-SOC08 *2 6 CS1W-OD292 2 Fujitsu connectors (56p) (2, 48-point connectors) Sourcing (PNP) 1:3 --- 2 PNP outputs G70D-SOC16-1/FOM16-1 6 Mixed I/O Units DC Transistor Output Units 32 inputs/ 32 outputs CS1W-MD261 2 Fujitsu connectors (40p) (1 for 32 inputs and 1 for 32 outputs) Outputs:

Sinking (NPN) B 1:2 XW2Z-RO@C-@ 1 NPN outputs G70D-SOC16/FOM16 2 1:2 XW2Z-RO@C-@ 1 NPN outputs G70D-VSOC16/VFOM16 2 1:2 XW2Z-RO@C-@ 1 NPN outputs G70D-SOC08 *2 2 1:2 XW2Z-RO@C-@ 1 NPN outputs G70R-SOC08 *2 2 CS1W-MD262 2 Fujitsu connectors (40p) (1 for 32 inputs and 1 for 32 outputs) Outputs: Sourcing (PNP) 1:2 XW2Z-RO@C-@ 1 PNP outputs G70D-SOC16-1/FOM16-1 2 48 inputs/ 48 outputs CS1W-MD291 2 Fujitsu connectors (56p) (1 for 48 inputs and 1 for 48 outputs) Outputs:

Sinking (NPN) D 1:3 XW2Z-R@C-@-@ 1 NPN outputs G70D-SOC16/FOM16 3 1:3 XW2Z-R@C-@-@ 1 NPN outputs G70D-VSOC16/VFOM16 3 1:3 XW2Z-R@C-@-@ 1 NPN outputs G70D-SOC08 *2 3 1:3 XW2Z-R@C-@-@ 1 NPN outputs G70R-SOC08 *2 3 CS1W-MD292 2 Fujitsu connectors (56p) (1 for 48 inputs and 1 for 48 outputs) Outputs: Sourcing (PNP) 1:3 --- 1 PNP outputs G70D-SOC16-1/FOM16-1 3