omron — Configure Network Properties

2 Configure Gigabit Ethernet Adapter(s) In Your PC to Use Static IP Setting Up the GigE Camera On the General Tab select “Use the following IP address” radio button and enter the IP address as 192.168.XXX.2 where XXX can be from 1 to 254. 192.168.XXX.UUU is a local private Class B network. The Subnet Mask is set for a Class C Network and the Default gateway is set to the same class C network with a host ID of 1. FIGURE 2–5. TCP/IP Property Page The setup of your network adapter is now complete. Visionscape software will automatically configure your Omron Microscan GigE cameras to be on the same network. Getting Started with Visionscape GigE Cameras 2-7