omron — Tutorial 4 — Using Measurement Tools in an Inspection

3 Tutorial 4 — Using Measurement Tools in an Inspection Advanced Tool Tutorials 45. Highlight Pin to Pin Distance tolerance (left pane). 46. In the Properties pane, set the following Pin to Pin Distance tolerance parameters: – Input Datum — Pin to Pin Distance.Pt-Pt Distance – With Tolerance — 5% Nominal 47. Minimize the Step Tree Editor. 48. Click . On the properties page, observe that the Nominal Distance is set to the output value of the above Pin to Pin Distance, the Tolerance+/- is set to be the value that is 5% of the Nominal Distance. 49. Minimize the Step Tree Editor. 50. Highlight Left to Center and click . 51. In the Properties (Figure 3–27), set Graphics Level to Show Graphics.

FIGURE 3–27. Select Reference Button Getting Started with Visionscape GigE Cameras 3-37