Hantek — Default Setting

controls according to input signals so that it can accurately display the waveform of the input signal. Cursor Off Display Format Set to YT Horizontal Position Adjusted SEC/DIV Adjusted Trigger Level Set to 50% Trigger Mode Auto Trigger Source Adjusted Trigger Slope Adjusted Trigger Type Edge Vertical Bandwidth Full Vertical Coupling Unchanged VOLTS/DIV Adjusted The Auto function examines all channels for signals and displays corresponding waveforms. Auto determines the trigger source according to the following conditions.  If multiply channels get signals, the oscilloscope will use the channel with the lowest frequency signal as the trigger source.

 If no signals are found, the oscilloscope will use the lowest-numbered channel displayed in Auto Scale as the trigger source.  If no signals are found and no channels are displayed, the oscilloscope will display and use Channel 1 as the trigger source. Default Setting Long press button, enter Short key setting menu, and select Default . Press button, pops up the prompt to recall the default settings on the screen, now press F1 to confirm. The oscilloscope will display the CH1 waveform and remove all the others. Press F4 to cancel. The table below gives the options, buttons and controls that change settings at default setup.

Type Off Source CH1 Cursor Horizontal (amplitude) ±4div Vertical (time) ±4div Display Format YT Horizontal Position 0.00s 11 Functions Settings Menu or Option, Button or Default Setting System Knob