Hantek · 25 стр.
HBT3000 series Quick Guide (EN)
Оригинальное название: HBT3000 series Quick Guide
Похожие инструкции
Текст документа
Warranties and Declarations Copyright The copyright of this document belongs to Qingdao Hantek Electronic Co., LTD. Statement Qingdao Hantek Electronic Co., Ltd. reserves the right to amend this document without prior notice. Qingdao Hantek Electronic Co., Ltd. promises that the information provided is correct and reliable but does not guarantee that this document is free from errors. Before using this product, please make sure that the specifications of relevant technical documents are the latest effective version.
If you use documents or products of Qingdao Hantek Electronic Co., LTD and need products, patents or works of third parties to cooperate with them, you shall be responsible for obtaining the consent and authorization of the third parties. The above consent and authorization shall not be the liability of Hantek. Product certification The Hantek certified HBT3000 series internal resistance tester meets Chinese national and industry standards, and has passed CE certification and UKCA certification. Contact Us If you have any questions or uncertainties while using the products of Qingdao Hantek Electronics Co., Ltd., you can obtain service and support through the following methods: Email:
service@hantek.com , support@hantek.com Website: http://www.hantek.com
Safety requirement CN 1 Safety requirement 1.1 Summary of general security issues Read the following safety precautions carefully to avoid injury and to prevent damage to this product or any product connected. To avoid possible dangers, please use this product in accordance with the regulations. ⚫ Only professionally authorized personnel can perform repairs. ⚫ Use the correct power cord. Only use the dedicated power cord recognized by the country where the product is located. ⚫ Ground the product. To avoid electric shocks, the product is grounded through a grounding conductor of the power cable.
The grounding conductor must be connected to the ground before connecting the input or output terminals of the product. Ensure that the product is properly grounded. ⚫ View all terminal rating values. To avoid fire or excessive current, please check all rating values and signs on the product. Please consult the product manual for details of the rating values before connecting the product. ⚫ Do not operate with the cover open. Do not run the product with the cover or panel open. ⚫ Avoid circuit exposure. Do not touch exposed connectors and components after power is switched on. ⚫ Do not operate if the product is suspected to be faulty.
If you suspect that the product has been damaged, please ask qualified maintenance personnel to check it. ⚫ Maintain proper ventilation. ⚫ Do not operate in a humid environment. ⚫ Do not operate in inflammable or explosive environment. ⚫ Please keep the product surface clean and dry. Warning: Equipment that meets Class A requirements may not provide adequate protection for broadcast services in residential environments.
Safety requirement CN 1.2 Security terms and signs Security terms in this manual: Warning: Indicates that the operation may not cause immediate damage to you. Warning: Indicates that if you perform this operation, it may not immediately cause damage to you. Note: Indicates that the operation may cause damage to the product or other property. Safety terms on products: Warning: Indicates a potential hazard may be caused to you if you do not perform this operation. Safety signs on the product: Environmental protection Warning Shell grounding terminal usage period identification 1.3 Measurement category Measurement category This instrument can be used for measurement under class I. Warning:
This instrument is only allowed to be used in the specified measurement class. Measurement class definition
Safety requirement CN ⚫ Class I refers to measurements taken on a circuit not directly connected to the main power supply. For example, measurements made on circuits that are not exported from a main power supply, especially from a protected (internal) main power supply. In the latter case, the instantaneous stress will change. Therefore, the user should understand the instantaneous capacity of the instrument. ⚫ Class II refers to measurements taken on a circuit directly connected to low- voltage instruments. For example, measurements made on household appliances, portable tools, and similar equipment. ⚫ Class III refers to measurements taken on construction equipment.
For example, measurements made on switchboards, circuit breakers, circuits (including cables, busbars, junction boxes, switches, sockets) in fixed equipment, as well as equipment for industrial use and certain other equipment (for example, fixed motors permanently connected to fixed instruments). ⚫ Class IV refers to measurements taken at the source of low-voltage equipment. For example, measurements made on electricity meters, primary overcurrent protection equipment, and pulse control units.
1.4 Ventilation Requirement To ensure sufficient ventilation, when using the instrument in a workbench or rack, please ensure that there is a gap of at least 10 centimeters on both sides, above, and behind it. Note: Poor ventilation can cause an increase in instrument temperature, leading to instrument damage. Good ventilation should be maintained during use, and ventilation openings should be regularly checked.
1.5 Work Environment Operating temperature and humidity range 0 ℃ -40 ℃, below 80% RH (without condensation) Storage temperature and humidity range -10 ℃ -50 ℃, below 80% RH (without condensation) Accuracy assurance temperature and humidity range 23 ° C ± 5 ° C, below 80% RH (without condensation) Warning: