Tachometer Tachometer Function code F5, Display Row 1 : Function code F10, Display Row 1 : Display Unit 0* Pulse per second (1/sec) P 0 Addtl. Upper limit 0* Disabled / no Output signal 1 Pulse per minute (1/min) 1 Additional range signal > P 0 Function code F6, Display Row 1 : Function code F11, Display Row 1 : 0* 1 Hz (if no further pulse is received after 1s, the display will return to 0) P 1 Lower limit 0* Disabled / no Output signal Min. Input frequency 0,1 Hz (if no further pulse is received after 1s, the display will return to 0) 1 1 Range signal Function code F12, Display Row 1 : Function code F7, Display Row 1 : 0* Disabled / no Output signal Startup- suppress.