Timer Timer Function code F3, Display Row 1 : Function code F6, Display Row 1 : PNP/NPN- Logic 0 NPN 8 V-Level dynam/ static Reset 0* Static Reset (as long as the signal is applied) 1* PNP 8 V-Level Dynamic Reset (ready to count after reset, even if reset signal is applied for a longer time) 1 2 NPN TTL-Level Function code F7, Display Row 1 : 3 PNP TTL-Level Timer- Mode of Operation Cumulative measurement - pulse- width (counts as long as Input A is active) Function code F4, Display Row 1 : 0 Input damping (Attenua tion) 0 30 Hz damping (attenuation) (e.g.
for mechanical contacts) 1* Cumulative measurement – cycle du ration (counts from rising edge of start signal to rising edge of stop sig nal). 1* F max. (see chapter 4 and 10) 2 Cumulative measurement - A=Run B=Stop (counts from rising edge of start sig nal to rising edge of stop signal). Set / Re set- Mode 0* Reset to 0 Function code F5, Display Row 1 : 3 Single-pulse measurement – pulse- width (counts as long as Input A is active) Single-pulse measurement – cycle du ration (counts from rising edge of start signal to rising edge of stop sig nal).
1 Automatic set to 0 after reaching Preset value 2 4 2 Set to Preset 2 Single-pulse measurement - A=Run B=Stop (counts from rising edge of start signal to rising edge of stop sig nal) 3 Automatically sets to Preset 2 after reaching 0. 5 72 73