Delta ISPSoft — 20.3.3 Communication Parameter Settings (Step 2)

ISPSoft User Manual  Transfer Capacity Mode The users can set 16 data exchange groups or 32 data exchange groups, depending on the model selected. The users can select a maximum data length in the Transfer Capacity Mode section. Besides, the maximum data length which can be set varies with the PLC which is designated as a master station. Please refer to manuals for more information.  Hold the RS485 Setting The communication parameters in a DVP series PLC will be restored to the default values if the DVP series PLC is turned on after a power failure.

However, if the Hold the RS485 Setting checkbox is selected, the host will switch from STOP to RUN and re-download the saved communication parameters; for more information on DVP COM port communication parameters, please refer to manuals regarding PLC types.  Synchronic R/W A master station sends a writing command and a reading command to a slave station separately. If the Synchronic R/W checkbox is selected, the master station can complete reading and writing simultaneously by means of a specific Modbus function code (the hexadecimal code 17), and the efficiency of data exchange is increased.

However, the users have to make sure that the devices involved in data exchange support the Modbus function code before they select the Synchronic R/W checkbox. If the devices do not support the Modbus function code, the Modbus code cannot be identified, and the reading/writing of data will fail after they receive the commands from the master station. For mode, choose 450 Words or users can only select Device D to enable Synchronic R/W.  Run PLC Link after downloading Select Run PLC Link after downloading . When finish planning PLC Link, download to hosts will also enable PLC Link. 20-44 Setting Description DVP AH5x1 16 Words A single data exchange transfer capacity length is 16 Words.

Use only Device D. V V 100 Words A single data exchange transfer capacity length is 100 Words. Use only Device D. V V 450 Words A single data exchange transfer capacity length is 450 Words and can use Device M, D or L. The device type for master and slave station can be different. V