Kuhnke — Quattro Relay 114

Quattro-Relais Quattro Relay 114 Coil Data Electrical Service Life OBSOLETE Electrical Service Life AC Switching Capability DC 90 % operating Below limiting characteristic: service life of contacts resistive load 2 x 10 4 switching cycles (90 % operating) conductive load resistive load cos ϕ = 0.4 ... 0.7 Service life of contact 10 5 Switching current in A 10 20 2 5 0.5 1 2 1 0.2 0.5 2 5 2 5 2 5000 100 1000 10 0.05 0.1 0.2 20 40 60 80 100 120 140 160 220 180 200 0 0.1 Switching capacity in VA Switching voltage in V Quattro Relay Standard Types in Stock available from stock in packs of 10 pcs each Kuhnke 21 Relay Catalogue Coil voltage DC 114A4 Pull-in power approx. 0.42 W Nom.

operation power approx. 1 W Coil voltage AC 114A4 Nom. operation power appr. 1.2/0.98 VA Inrush current appr.

1.5 x nominal current Nominal voltage (V) Nominal resistance (Ω) Nominal current (mA) Nominal voltage (V) Nominal resistance (Ω) Nominal current 50 Hz (mA) Nominal current 60 Hz (mA) 12 143 84 12 46.5 100 81 24 576 42 24 177 50 41 48 2250 21 48 762 25 20 110 12100 9 115 4570 10 8.5 120 4570 11 8.8 230 19040 5.2 4.2 E L DC AC 114 A4-12VDC1 114 A4B-24VDC1 114 A4-12VAC1 114 A4B-230VAC1 114 A4-12VDC1L 114 A4B-24VDCN 114 A4-24VAC1 114 A4B-230VACN 114 A4-12VDCN 114 A4-24VAC1L 114 A4-24VDC1 114 A4-24VACN 114 A4-24VDC1F1 114 A4-48VAC1 114 A4-24VDC1FL 114 A4-48VACN 114 A4-24VDC1FL1 114 A4-115VAC1 114 A4-24VDC1L 114 A4-115VAC1L 114 A4-24VDCN 114 A4-115VACN 114 A4-24VDCNF 114 A4-120VAC1 114 A4-24VDCNFL 114 A4-120VAC1L 114 A4-24VDCNFL1 114 A4-230VAC1 114 A4-48VDC1 114 A4-230VAC1L 114 A4-48VDC1L 114 A4-230VACN 114 A4-48VDCN 114 A4-230VACNL 114 A4-110VDC1 114 A4-110VDCN