LVS-7500 External System Installation and Quick Start Guide 11. Adjust the height of the horizontal bar so that the docking plate aligns as close as possible to the height of the printhead. Do this by loosening the quick lock handle and then slowly adjust the horizontal mounting bracket so that the readhead fits snugly against the printhead. When the ideal position is located, tighten the quick lock handle. See correct and incorrect placement examples in the next section. 12.

If the docking plate needs to move left or right to align with the printhead, simply loosen (do not remove) the two screws on the docking plate (using the 5/32” Allen key) and gently slide the docking plate to the ideal location. Then, tighten the two screws so that the docking plate secures firmly to the horizontal mounting bracket. See correct and incorrect placement examples in the next section. Note: The docking plate must always be positioned between the two brackets supporting the internal rewind bar; thus if the docking plate is moved, the internal rewind bar must also be moved. 13.

Run labels through the printer and over the docking plate paying close attention to the placement of the labels. The labels should feed directly onto the docking plate and lay as straight as possible. The labels should NOT move up, down, or diagonally from the printhead onto the docking plate. See the following examples. LVS-7500 External System Installation and Quick Start Guide Page 33 of 45