Lynkco — Lynkco инструкция

Lynk&Co Lynk&Co 03 TCR Limit Support Points fEngRpm pManifold rLambda Engine B4204T27 4200 2420 - ECU Make (Type) MoTeC (Motorsport) 4450 2420 - Gearbox any 4700 2420 - ECU Type & Power Level M4 4950 2435 - Calibration File LynkCo 03 TCR Engine Custom ECU 97% v2.02 5200 2450 - Correction [mbar/°C] 4 5450 2460 - 5700 2470 - units:

[1/min] for fEngRpm, [mbar] for pManifold 5950 2470 - 6200 2470 - 6450 2480 - 6700 2490 - 6950 2470 - 7100 2460 - 7200 2440 - Lynk&Co 03 TCR Limit Support Points fEngRpm pManifold rLambda Engine B4204T27 4000 2335 - ECU Make (Type) TCR ECU (Common) 4250 2240 - Gearbox any 4500 2065 - ECU Type & Power Level C4 4750 2040 - Calibration File LY-B4204T27-C-X-S 2.0.0.clx _ 5000 2045 - Correction [mbar/°C] 9 5250 2350 - Checksum crcAPP 0x12346563 5500 2480 - crcPartSign 0xB51ED49A 5750 2510 - crcPartZero 0x3CA1744E 6000 2555 - crcPartOne 0x4B4A6054 6250 2580 - 6500 2565 - units: [1/min] for fEngRpm, [mbar] for pManifold 6750 2450 - 6900 2430 - 7000 2110 -