MicroHAWK ® MV-20 / MV-30 / MV-40 Configuration Guide Hardware Required Configurations MicroHAWK MV-20 with Micro-USB Type B to USB Type A USB Type A Plug MicroHAWK MV-30 with DB15 to BUS Power USB Type A Accessory USB MicroHAWK MV-30 with DB15 to Ext. Power/USB Type A Accessory USB Cable to Host 9 To Host Integrated Corner-Exit Cable Power Supply 6 1 Copyright ©2019 Omron Microscan Systems, Inc.

83-9217013-02 Rev H Item Description Part Number 1 MicroHAWK MV-20, MicroHAWK MV-30, or MicroHAWK MV-40 7ABX-YZZZ-LPPP 2 Cable, USB A to Micro B, 6 ft., MV-20 61-9000034-01 3 Cable, USB A to Micro B, 3 ft., MV-20 61-9000045-01 4 Cable, DB15 to BUS Power USB Type A, MV-30 61-9000043-01 5 Kit, Cable, DB15 to Ext. Power/RS-232 with Power Supply, MV-30 – includes 97-9000006-01 and 61-9000037-01 98-9000048-01 6 Power Supply, 5V – for use with cables 61-9000037-01 and 61-9000038-01 97-9000006-01 7 Cable, DB15 to Ext. Power/RS-232, MV-30 61-9000037-01 8 Kit, Cable, DB15 to Ext. Power/USB with Power Supply, MV-30 – includes 97-9000006-01 and 61-9000038-01 98-9000049-01 9 Cable, DB15 to Ext.

Power/USB, MV-30 61-9000038-01 10 Kit, Cable, DB15 to Ext. Power/USB, I/O with Power Supply, MV-30 – includes 97-000011-02 and 61-9000039-01 98-9000050-01 11 Power Supply, 100-240VAC, +5VDC, 2-Pin U.S./Euro Plug 97-000011-02 12 Cable, DB15 to Ext. Power/USB, I/O, MV-30 61-9000039-01 13 Power Supply, 100-240VAC, +24VDC, TRK 3-Pin, U.S./Euro Plug 97-000012-02 14 IB-131 Interface Box 99-000018-01 15 Converter, IC-332, 24V/5V, Opto I/O – for use with IB-131 FIS-0001-0035G 16 Cable, Communication, DB25 Plug to DB9 Socket, 6 ft.

61-3000026-03 17 Photo Sensor, Visible, NPN, Light On, 5VDC 99-000019-01 18 Cable, DB15 to USB/RS-232, Triggered, MV-30 61-9000102-01 19 Power Supply, 100-240VAC, +24VDC, M12 12-Pin Socket 97-000012-01 20 QX-1 Interface Device 98-000103-02 21 Cordset, Common, M12 12-Pin Socket (Screw-On) to M12 12-Pin Plug 61-000162-02 22 Cordset, Host, Ethernet, M12 8-Pin Plug (Screw-On) to RJ45, 1 m. 61-000160-03 23 Photo Sensor, M12 4-Pin Plug, NPN, Dark On or Light On (Selectable), 2 m.

99-9000016-01 24 Cable, M12 12-Pin Socket to 9-Pin Socket and M12 Plug 61-9000054-01 25 Cable, M12 12-Pin Socket to USB Keyboard Wedge and M12 Plug 61-9000088-01 2 or 3 Micro-USB Type B Plug 1 To Host Cable to Host 4 Integrated Corner-Exit To Host Cable Note: BUS-powered cable delivers reduced illumination – approximately 30% less brightness. 1

Стр. 1

MicroHAWK MV-20 / MV-30 / MV-40 Configuration Configurations (continued) MicroHAWK MV-30 with DB15 to Ext. Power/USB, I/O MicroHAWK MV-30 with DB15 to USB/RS-232, Triggered To Trigger 1 MicroHAWK MV-30 with IB-131 and IC-332 1 Copyright ©2019 Omron Microscan Systems, Inc. MicroHAWK MV-30 with DB15 to Ext. Power/RS-232 To host Integrated 7 Corner-Exit Cable 6 Power 1 Supply To Trigger 12 Accessory Integrated USB Cable Corner-Exit to Host Cable To Power Supply 1 To Hos To Pow Accessory USB Cable to Host t (USB) 18 Integrated Corner-Exit er Supply (11) Cable To Host (RS-232) To Hos IC-332 15 16 IB-131 14 t To To ex power trigge supply 13 17

Стр. 2

MicroHAWK MV-20 / MV-30 / MV-40 Configuration Configurations (continued) MicroHAWK MV-40 with QX-1 Interface Device 19 23 MicroHAWK MV-40 M12 12-Pin Socket to 9-Pin Socket and M12 Plug To Power Supply (19) or: Flying Lead Cable (61-000167-02); QX-1; MS-Connect 210. 1 24 To Host (RS-232) To Ethernet Copyright ©2019 Omron Microscan Systems, Inc. 0 1 21 22 Common (12-Pin Plug to 12-Pin To Ho Socket) (Ether 8-Pin to RJ4 QX-1 To Power Supply To Trigger

Стр. 3

MicroHAWK MV-20 / MV-30 / MV-40 Configuration Electrical Specifications MicroHAWK MV-20: 5VDC ± 5% , 350 mA at 5VDC (typ.) MicroHAWK MV-30: 5V DC ± 5% , 600 mA at 5VDC (typ.) MicroHAWK MV-40: 4.75 – 30V DC, 200 mV p-p max ripple, 150 mA at 24VDC (typ.) Important: See the MicroHAWK MV-20 / MV-30 / MV-40 Smart Camera Guide for information about Omron Microscan’s Isolation Mounting Kit (P/N 98-9000064-01) to eliminate ground loops or other external electrical noise through your MicroHAWK MV-30 or MV-40 camera.

MicroHAWK MV-20 Micro-USB Type B Socket MicroHAWK MV-40 M12 Connectors Output 2 New Master Default Power Output 1 Output 3 RS-232 (Host) TxD Ground Trigger MicroHAWK MV-30 High-Density 15-Pin Dsub USB/Serial Socket Input Common Output Common RS-232 (Host) RxD M12 12-Pin Plug TX (+) V+ RX (–) V+ Note: An accessory cable is required between the MV-30’s 15-pin corner-exit cable and the host’s USB port. RX (+) TX (–) V– M12 8-Pin Socket (Ethernet) V– QX-1 Interface Device – for use with the MicroHAWK MV-40 (Top View) Trigger P Connector T on the QX-1 Interface Device is the trigger connector. Connectors 1 , 2 , and 3 can be used to bus power and data as required by the application.

Ground +10-28V T Trigger/New Master / Input 1 Common QX-1 Trigger Connector (T) 4-pin Socket Copyright © 2019 Omron Microscan Systems, Inc. Pin Function 1 Vbus (5V) 2 D– 3 D+ 4 N/C 5 Ground Pin Function 1 +5VDC 2 TX232 3 RX232 4 GND 5 D+ 6 N/C 7 Output 1+ 8 Default+ 9 Trigger+ 10 D– 11 Output 3+ 12 New Master+ 13 N/C 14 Output 2+ 15 Vbus