Delta — Load Cell Module DVP02LC-SL — Operation Manual by Delta Electronics (EN)

Load Cell Module DVP02LC-SL 4.4 External Wiring 4 strain guage A+5V AGND CH1 6 strain guage A+5V AGND CH2 Terminal of power module System grounding *1 DC/DC A+5V AGND Converter Grounding (100 or less) Many load cells connected in parallel connected to a single DVP02LC-SL: Load Cell Load Cell DVP02LC Load Cell CH1 Load Cell Load Cell CH2 Load Cell Load Cell Load Cell Note 1: Please connect the on both the power module and load cell module to the system earth point and ground the system contact or connect it to the cover of the power distribution cabinet. Note 2: When many load cells are connected in parallel, the total impedance shall be bigger than 40Ω.

DVP-PLC Operation Manual 8 EXC+ EX C- SIG+ SIG- SEN+ SEN- EXC+ EXC- SIG+ SIG- SEN+ SEN- 0V 24V