Load Cell Module DVP02LC-SL 5 Functions of DVP02LC-SL 5.1 Control Registers (CR) DVP-PLC Operation Manual 9 CR# Address Attribute Content b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 #0 H’1000 O R Model name Set up by the system. DVP02LC-SL model code = H’4206 #1 H’1001 O R Firmware version Displaying the current firmware version in hex. #2 H’1002 O R/W Eigenvalue Mode 0 (H’0000): 1 mV/V Mode 1 (H’0001): 2 mV/V (Default) Mode 2 (H’0002): 4 mV/V Mode 3 (H’0003): 6 mV/V #3 H’1003 O R/W Reaction time for measurement Mode 0 (H’0000): 2 ms Mode 1 (H’0001): 10 ms Mode 2 (H’0002): 20 ms Mode 3 (H’0003): 40 ms Mode 4 (H’0004):
80 ms (Default) #4 H’1004 O R Average value of all channels Summing up the CH1 average value and CH2 average value and equalizing them. Equation = (CH1 average value + CH2 average value) ÷ 2 #6 H’1006 X R/W CH1 to CH2 read tare weight Reading the present average value as the tare weight value. bit0: CH1; bit1: CH2; bit2 to bit15: reserved #7 H’1007 O R/W CH1 to CH2 gross/net weight Selecting the present weight to be gross weight (K0) or net weight (K1). bit0 to bit3: CH1; bit4 to bit7: CH2; bit8 to bit15: reserved Take CH1 for example:
bit3 to bit0 = 0000 (gross); bit3 to bit0 = 0001 (net); bit3 to bit0 =1111 (channel disabled) #8 H’1008 O R/W CH1 tare weight The user can write in the weight or read it by commands. Default: K0; Range: K-32,768 to K32,767 #9 H’1009 O R/W CH2 tare weight #10 H’100A O R/W CH1 average times Default: K10; Range: K1 to K100 When the value exceeds the range, it will automatically be changed to K1 or K100. #11 H’100B O R/W CH2 average times #12 H’100C X R CH1 average weight Displaying the average weight. #13 H’100D X R CH2 average weight #14 H’100E X R CH1 present weight Displaying the present weight. #15 H’100F X R CH2 present weight #16 H’1010 O R/W CH1 times of standstill check Default:
K5 Range: K1 to K500 #17 H’1011 O R/W CH2 times of standstill check #18 H’1012 O R/W CH1 range for standstill check Default: K10 Range: K1 to K10,000 #19 H’1013 O R/W CH2 range for standstill check #20 H’1014 O R/W CH1 decimal point place Default: K2 Range: K1 to K4 #21 H’1015 O R/W CH2 decimal point place