Revision 2016/03, 6ELE, V1.14 4-7 Parameter Function Setting Factory Setting Customer 02.08 Accel/Decel Rate of Change of UP/DOWN Operation with Constant Speed 0.01~10.00 Hz 0.01 02.09 Source of Second Frequency Command 0: Digital keypad UP/DOWN keys or Multi- function Inputs UP/DOWN. Last used frequency saved. 1: 0 to +10V from AVI 2: 4 to 20mA from ACI 3: RS-485 (RJ-45) communication 4: Digital keypad potentiometer 0 02.10 Combination of the First and Second Master Frequency Command 0: First Master Frequency Command 1: First Master Frequency Command+ Second Master Frequency Command 2:
First Master Frequency Command - Second Master Frequency Command 0 02.11 Keypad Frequency Command 0.00 to 599.0Hz 60.00 02.12 Communication Frequency Command 0.00 to 599.0Hz 60.00 02.13 The Selections for Saving Keypad or Communication Frequency Command 0: Save Keypad & Communication Frequency 1: Save Keypad Frequency only 2: Save Communication Frequency only 0 02.14 Initial Frequency Selection (for keypad & RS485) 0: by Current Freq Command 1: by Zero Freq Command 2: by Frequency Display at Stop 0 02.15 Initial Frequency Setpoint (for keypad & RS485) 0.00 ~ 599.0Hz 60.00 02.16 Display the Master Freq Command Source Read Only Bit0=1: by First Freq Source (Pr.02.00) Bit1=1:
by Second Freq Source (Pr.02.09) Bit2=1: by Multi-input function ## 02.17 Display the Operation Command Source Read Only Bit0=1: by Digital Keypad Bit1=1: by RS485 communication Bit2=1: by External Terminal 2/3 wire mode Bit3=1: by Multi-input function ## 02.18 User-defined Value 2 Setting 0 to Pr.00.13 0 02.19 User-defined Value 2 0 to 9999 ##