Chapter 4 Parameters | Group 3 Output Function Parameters 4-8 Revision 2016/03, 6ELE, V1.14 Parameter Function Setting Factory Setting Custome r 03.00 Multi-function Output Relay (RA1, RB1, RC1) 0: No function 1: AC drive operational 2: Master frequency attained 3: Zero speed 4: Over torque detection 5: Base-Block (B.B.) indication 6: Low-voltage indication 7: Operation mode indication 8: Fault indication 9: Desired frequency attained 10: Terminal count value attained 11: Preliminary count value attained 12: Over Voltage Stall supervision 13: Over Current Stall supervision 14: Heat sink overheat warning 15: Over Voltage supervision 16: PID supervision 17: Forward command 18:
Reverse command 19: Zero speed output signal 20: Warning(FbE,Cexx, AoL2, AUE, SAvE) 21: Brake control (Desired frequency attained) 22: AC motor drive ready 23: Multi-pump system error display (only master) 8 03.01 Reserved 03.02 Desired Frequency Attained 0.00 to 599.0Hz 0.00 03.03 Analog Output Signal Selection (AFM) 0: Analog frequency meter 1: Analog current meter 0 03.04 Analog Output Gain 1 to 200% 100 03.05 Terminal Count Value 0 to 9999 0 03.06 Preliminary Count Value 0 to 9999 0 03.07 EF Active When Terminal Count Value Attained 0: Terminal count value attained, no EF display 1: Terminal count value attained, EF active 0 03.08 Cooling Fan Control 0: Fan always ON 1:
1 minute after AC motor drive stops, fan will be OFF 2: Fan ON when AC motor drive runs, fan OFF when AC motor drive stops 3: Fan ON when preliminary heatsink temperature attained 4: Fan ON when AC motor drive runs, fan OFF when AC motor drive stops. Fan is at standby mode when AC is at 0Hz. 0