Delta — Руководство по эксплуатации Microsoft DVP24SV2 (EN)

On->Off: Continuing to output the pulses which have not been output M1310 For EH/EH2/SV/EH3/SV2, Off->On: The first high-speed pulse output CH2 (Y4, Y5) pauses immediately. On->Off: Continuing to output the pulses which have not been output M1311 For EH/EH2/SV/EH3/SV2, Off->On: The first high-speed pulse output CH3 (Y6, Y7) pauses immediately. On->Off: Continuing to output the pulses which have not been output M1326 For 24SV2, after CH4 completes the production of pulse output, M1326 will be On. M1327 For 24SV2, after CH5 completes the production of pulse output, M1327 will be On. M1335: For EH, CH1 pulse output pauses. For EH2/SV/EH3/SV2, CH1 pulse output stops. M1336:

For EH/EH2/SV/EH3/SV2, “CH0 sends out pulses” indication. M1337: For EH/EH2/SV/EH3/SV2, “CH1 sends out pulses” indication. M1347: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH0 pulse output. M1348: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH1 pulse output. M1520: For EH2/SV/EH3/SV2, CH2 pulse output stops. M1521: For EH2/SV/EH3/SV2, CH3 pulse output stops. M1522: For EH2/SV/EH3/SV2, “CH2 sends out pulses” indication. M1523: For EH2/SV/EH3/SV2, “CH3 sends out pulses” indication. M1524: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH2 pulse output. M1525: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH3 pulse output. M1534:

For EH2/SV/EH3/SV2, designated deceleration time of CH0 (should be used with D1348). M1535: For EH2/SV/EH3/SV2, designated deceleration time of CH1 (should be used with D1349). M1536: For EH2/SV/EH3/SV2, designated deceleration time of CH2 (should be used with D1350). M1537: For EH2/SV/EH3/SV2, designated deceleration time of CH3 (should be used with D1351). M1532: For EH2/SV/EH3/SV2, direction signal of CH2. M1533: For EH2/SV/EH3/SV2, direction signal of CH3. M1568 For 24SV2, users can set the time it takes for CH4 to decelerate the production of pulse output. It is used with D1196. M1569 For 24SV2, users can set the time it takes for CH5 to decelerate the production of pulse output.

It is used with D1197. 3. Special registers for EH/EH2/SV/EH3/SV2 series MPU: D1022 For 24SV2, users can set the frequency with which the first section of the pulse output produced by CH4 starts, and the frequency with which the last section of the pulse output produced by CH4 ends. D1023 For 24SV2, users can set the frequency with which the first section of the pulse output produced by CH4 starts, and the frequency with which the last section of the pulse output D1030 For 24SV2, the number of pulses produced by CH4 (Low word) produced by CH4 ends.