EPSON — Supplying and Adjusting Compressed Air

Workflow before Beginning Work Supplying and Adjusting Compressed Air Compressed air is supplied in order for the machine to operate. The machine will not operate if the specified air pressure is not supplied. An air pressure that is higher than the specified air pressure could cause the machine to malfunction. Please check the air pressure before operating the machine. Supplying the air pressure Turn the red valve on the air supply regulator counterclockwise to change the indicator for the valve from “EXH” to “SUP”. Confirm that the meter moves and that air is supplied.

Valve Checking and adjusting the air pressure Confirm that the pressure indicated by the meter on the air supply regulator is within the range stipulated in the specifications. For air pressure specifications, refer to "Power" on Page 132 . Use the pressure adjustment handle to adjust the air pressure as necessary. 1 Make sure that the valve is set to “SUP” (air pressure is applied). 2 Check the pressure indicated by the meter, and use the pressure adjustment handle to adjust the air pressure as necessary. Clockwise: Raises the pressure. Counterclockwise: Lowers the pressure. If the pressure does not rise to the specified value, adjust the pressure in the factory.

Pressure adjustment handle Meter 29