Victron Energy MultiPlus 2kVA 230V — 5.4.2. Exemplary settings

MultiPlus 2kVA 230V A MK3-USB (VE.Bus to USB) interface. Alternatively, the Interface MK2.2b (VE.Bus to RS232) can be used (RJ45 UTP cable needed). 5.3.1. VE.Bus Quick Configure Setup VE.Bus Quick Configure Setup is a software program with which systems with a maximum of three MultiPlusses (parallel or three phase operation) can be configured in a simple manner. The software can be downloaded free of charge at www.victronenergy.com. 5.3.2. VE.Bus System Configurator For configuring advanced applications and/or systems with four or more MultiPlusses, VE.Bus System Configurator software must be used. The software can be downloaded free of charge at www.victronenergy.com 5.4.

Configuration with DIP switches Some settings can be changed with DIP switches. Procedure: a) Turn the MultiPlus on, preferably without load and without AC voltage on the input. The MultiPlus will then operate in inverter mode. b) Set the DIP switches as required. c) Store the settings by toggling DIP switch 3 one time. 5.4.1. DIP switch 1 to 3 These DIP switches can be used to set: Battery charge voltage and Absorption time Search mode Ds1-ds2: Setting the charge algorithm (For more system settings use VEConfigure) DS3 double function. Ds3: Search Mode and store off = off on = on Store the settings by toggling DIP switch 3 one time. 5.4.2.

Exemplary settings Example 1 is the factory setting (since factory settings are entered by computer, all DIP switches of a new product are set to ‘off’).

Page 13 Configuration Ds1-ds2 Absorption voltage Float voltage Storage Voltage Absorption Time (hours) Suitable for Ds1=off Ds2=off (default) 14.4 28.8 57.6 13.8 27.6 55.2 13.2 26.4 52.8 8 Gel Victron Deep Discharge Gel Exide A200 AGM Victron Deep Discharge Ds1=on Ds2=off 14.1 28.2 56.4 13.8 27.6 55.2 13.2 26.4 52.8 8 Gel Victron Long Life (OPzV) Gel Exide A600 (OPzV) Gel MK battery Li-ion (LiFePO4) Ds1=off Ds2=on 14.7 29.4 58.8 13.8 27.6 55.2 13.2 26.4 52.8 5 AGM Victron Deep Discharge Tubular plate or OPzS batteries in semi-float mode AGM spiral cell Ds1=on Ds2=on 15.0 30.0 60.0 13.8 27.6 55.2 13.2 26.4 52.8 6 Tubular plate or OPzS batteries in cyclic mode