4 Screen Creation User should use this method to create total 8 screens for this project, the screen No. and names are listed as below: 2 Double-click “Wait” Screen to open [Screen Property], select “Background Color” and set “Background Color” to “lightCyan”. z Bit Button Component 1 Bit Button component for switching to the maintenance screen The Bit Button component is placed on the upper left corner of the screen. Pressing this hiding button (Bit Button component) to switch to maintenance screen ([6 Check 1] screen). Function: Pressing the button and turn ON W_bit0.02, the display of PT will be switched to [6. check 1] by the ladder program of CP1E.
The Function Key is set transparent and will not function until being pressed for 3 seconds for the purpose of avoiding being pressed accidentally. Select [Bit Button component] from [Parts], drag it to the edit window after selecting it with a single-click. The property settings are: 4-14 NB-series Programmable Terminals Startup Guide Manual(V109) Screen No Screen Name 10 Wait 11 Open 12 Close 13 Stop 14 Fully Open 15 Check1 16 Check2 17 Check3 Write Address W bit0.02 _ Bit Button Types On Graphics Use the vector graphic: Dashed.vg (A vector graphic created by user, which is a light cyan rectangle) Control Setting (Security Setting) ON Delay 3s