1. Connection Procedure for Remote Access 6.3.2. Access to the SiteManager Access from your personal computer to the SiteManager. Precautions for Correct Use If your personal computer is connected to the internet via WiFi connection or other methods, disconnect from the internet. The following SiteManager settings may not be applicable unless you disconnect the internet. Startup Guide – Remote Access - RT1 Series - P151-E1-02 23 1 Make sure Personal computer is not connected to the internet via WiFi connection or other methods. 2 Change the IP address and subnet mask of Ethernet port on Personal computer to belong to the same subnet as DEV ports on SiteManager.

In this guide, they are set as follows: ・IP address: 10.0.0.2 ・Subnet mask: 255.255.255.0 *The IP address (default) of DEV1–DEV3 ports on SiteManager is as follows: ・IP address: 10.0.0.1 ・Subnet mask: 255.255.255.0 *If SiteManager is not in the factory default settings, initialize SiteManager by referring to Section 7. Initialization Method. 3 Turn ON SiteManager and check that the startup is completed. *The completion of startup can be checked by STATUS LED changing from Steady RED blink to On RED.