PanelScan Integration Guide Remote Job Setting: Product List This table is used as a lookup table for product names and corresponding jobs. This can be found and configured in the PanelScan user interface under Menu > Config > Product Table Configuration . If using the *LOADJOB command, the software will take the product name and load the corresponding job. Many products can be associated with the same job. All product names should be different. If two products share the same name, the first job path will be used. Other Information • PanelScan is the server. The user-created connection must be the client. • The end of the command sent by PanelScan is a CR ( \x000d ).
CSV Output • When using TCP/IP, PanelScan will create a “WorkOrder_FamilyID_DateTime” folder for each Lot. • Save all CSV files for the Lot with the naming scheme “WorkOrder_FamilyID _TrayNo.csv” . • For each location in the tray, the CSV file will read either the data “NO READ” or “EMPTY” . “EMPTY” is used in the pre-determined slots of the partial tray. Calling an External .exe To call an external .exe file, check the box for Call external program , specify the file path for the .exe, and use the dropdown menus to select the optional parameters to send the program. The current options are None , PanelID , and PassFail . Contact Omron Microscan if additional parameter options are required.
16 Copyright © 2019 Omron Microscan Systems, Inc.