Model Numbering
TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 300W 1 Phase / PMT-5V350W1A PMT Highlights & Features AC input range selectable by switch Full Aluminium casing for light weight and corrosion resistant handling Built-in automatic fan speed control circuit Wide operating temperature range from -20 ° C to +70 ° C and cold start at -40 ° C MTBF > 700,000 hrs. as per Telcordia SR-332 Short Circuit / Overvoltage / Overload / Over Temperature Protections Safety Standards CB Certified for worldwide use Model Number: PMT-5V350W1A Unit Weight : 0.81 kg Dimensions (L x W x D):
215 x 115 x 50 mm General Description The new PMT series of panel mount power supplies is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. PMT-5V350W1A offers a nominal output voltage of 5V with a wide operating temperature range from -20°C to +70°C and can withstand shock and vibration (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta’s PMT series of panel mount power supplies is unlike many other brands in the same price level.
The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and will have no output power de- rating from 100Vac to 132Vac & 180Vac to 264Vac. Model Information PMT Panel Mount Power Supply Model Numbering 1 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev.
00) Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A□□ 90-132Vac, 180-264Vac (Selectable by Switch) 5Vdc 60.0A CC Code PM T – 5V 350W 1 A □ □ Panel Mount Product Type T – Enclosed Output Voltage Output Power (350W series model) Single Phase No PFC Series Connector Type M – Terminal Block G – Front Face Blank – Without connector cover A – With connector cover
Mechanical
TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 300W 1 Phase / PMT-5V350W1A Specifications Input Ratings / Characteristics Output Ratings / Characteristics Mechanical 2 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev.
00) Nominal Input Voltage 100-120Vac, 200-240Vac (Selectable by Switch) Input Voltage Range 90-132Vac, 180-264Vac (Selectable by Switch) Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current Efficiency at 100% Load > 76.0% @ 230Vac Max Inrush Current Leakage Current Nominal Output Voltage 5Vdc Output Voltage Tolerance ± 3% (initial set point tolerance from factory) Output Voltage Adjustment Range 4.50-5.60Vdc Output Current 60.0A Output Power 300W Line Regulation ± 0.5% typ. Load Regulation ± 2.5% typ.
PARD (20MHz) Rise Time Start-up Time Hold-up Time > 16ms @ 115Vac, > 20ms @ 230Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 1000mVpp @ 10-50% load and 50-100% load Start-up with Capacitive Loads 8,000µF Max Case Chassis Aluminium Case Cover Aluminium Dimensions (L x W x D) 215 x 115 x 50 mm Unit Weight 0.81 kg Indicator Green LED (DC OK) Cooling System Forced Cooling Terminal PMT-5V350W1AM M3.5 x 9 Pins (Rated 300V/15A) PMT-5V350W1AG M3.5 x 9 Pins (Rated 300V/20A) Wire AWG 14-12
Safety Standards / Directives
TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 300W 1 Phase / PMT-5V350W1A Environment Protections *PE: Primary Earth Reliability Data Safety Standards / Directives 3 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev. 00) Surrounding Air Temperature Operating -20°C to +70°C Storage -40°C to +85°C Power De-rating > 50°C de-rate power by 4% / °C, > 60°C de-rate power by 1% / °C Operating Humidity Operating Altitude 5,000 Meters Shock Test (Non-Operating) IEC60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total Vibration Operating IEC60068-2-6, Sine Wave:
10Hz to 150Hz @ 25m/S² (2.5G peak); 90 min per axis for all X, Y, Z direction Non-Operating IEC60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms peak; 20 min per axis for all X, Y, Z direction Pollution Degree 2 Overvoltage Overload / Overcurrent > 105~135% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery) Over Temperature Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) Short Circuit Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection MTBF > 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta:
35°C Expected Cap Life Time Expected Cap Life Time Electrical Safety UL/cUL recognized to UL60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC60950-1 Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0KVac Input to Ground 1.5KVac Output to Ground 0.5KVac
EMC
TECHNICAL DATASHEET PMT Panel Mount Power Supply 5V 300W 1 Phase / PMT-5V350W1A EMC 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) *Fulfills tested conditions 4 All parameters are specified at 25°C ambient unless otherwise noted. www.DeltaPSU.com (August 2013, Rev. 00) EMC / Emissions* CISPR22, EN55022, FCC Title 47: Class A (With Delta EMI filter P/N: 10DKAW5) Immunity to* EN 55024 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A1) Air Discharge: 15kV Contact Discharge:
8kV Radiated Field IEC61000-4-3 Level 3 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A1) 2kV Surge IEC61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Conducted IEC61000-4-6 Level 3 Criteria A1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC61000-4-8 Criteria A1) 10A/Meter Voltage Dips IEC61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC61000-4-12 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Harmonic Current Emission NA Voltage Fluctuation and Flicker* IEC/EN 61000-3-3