omron — 2.7. I/O Function Assignment

(1) Input interrupt, quick-response input function Function assignments have not been changed. The CP2E-N□□ includes an increased number of interrupt inputs and quick-response inputs. Contact function assignments (2) High-speed counter input function changes Although the max. input frequency has been increased, function assignments have not been changed. Max.

input frequency Contact function assignments 7 Input contac t CP1E CP2E CP2E-S/E, CP2E-N14 CP2E-N20/30/40/60 0.02 Interrupt input 2/ Quick-response input 2 Interrupt input 2/ Quick-response input 2 Interrupt input 2/ Quick-response input 2 0.03 Interrupt input 3/ Quick-response input 3 Interrupt input 3/ Quick-response input 3 Interrupt input 3/ Quick-response input 3 0.04 Interrupt input 4/ Quick-response input 4 Interrupt input 4/ Quick-response input 4 Interrupt input 4/ Quick-response input 4 0.05 Interrupt input 5/ Quick-response input 5 Interrupt input 5/ Quick-response input 5 Interrupt input 5/ Quick-response input 5 0.06 Interrupt input 6/ Quick-response input 6 Interrupt input 6/ Quick-response input 6 Interrupt input 6/ Quick-response input 6 0.07 Interrupt input 7/ Quick-response input 7 Interrupt input 7/ Quick-response input 7 Interrupt input 7/ Quick-response input 7 0.08 - - Interrupt input 8/ Quick-response input 8 0.09 - - Interrupt input 9/ Quick-response input 9 High-speed CP1E-E(S) CP1E-N(S) CP2E-S/E CP2E-N counter High-speed counter 0 Increment pulse:

10 kHz Increment/decrement pulse: 10 kHz Pulse + direction: 10 kHz Phase difference: 5 kHz Increment pulse: 100 kHz Increment/decrement pulse: 100 kHz Pulse + direction: 100 kHz Phase difference: 50 kHz Increment pulse: 100 kHz Increment/decrement pulse: 100 kHz Pulse + direction: 100 kHz Phase difference: 50 kHz Increment pulse: 100 kHz Increment/decrement pulse: 100 kHz Pulse + direction: 100 kHz Phase difference: 50 kHz High-speed counter 1 Increment pulse: 10 kHz Increment/decrement pulse: 10 kHz Pulse + direction: 10 kHz Phase difference: 5 kHz Increment pulse: 100 kHz Increment/decrement pulse: 10 kHz Pulse + direction: 100 kHz Phase difference: 5 kHz Increment pulse:

100 kHz Increment/decrement pulse: 10 kHz Pulse + direction: 100 kHz Phase difference: 5 kHz N30/40/60 Increment pulse: 100 kHz Increment/decrement pulse: 100 kHz Pulse + direction: 100 kHz Phase difference: 50 kHz N14/20 Increment pulse: 100 kHz Increment/decrement pulse: 10 kHz Pulse + direction: 100 kHz Phase difference: 5 kHz High-speed counter 2 Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse: 100 kHz High-speed counter 3 Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse: 10 kHz High-speed counter 4 Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse:

10 kHz High-speed counter 5 Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse: 10 kHz Increment pulse:

10 kHz Input contact For both CP1E and CP2E Increment pulse Differential phase or up/down Pulse + direction 0.00 High-speed counter 0 High-speed counter 0 (phase A/increment) High-speed counter 0 (pulse) 0.01 High-speed counter 1 High-speed counter 0 (phase B/decrement) High-speed counter 1 (pulse) 0.02 High-speed counter 2 High-speed counter 1 (phase A/increment) High-speed counter 0 (direction) 0.03 - High-speed counter 1 (phase B/decrement) High-speed counter 1 (direction) 0.04 High-speed counter 3 High-speed counter 0 (phase Z/reset) High-speed counter 0 (reset) 0.05 High-speed counter 4 High-speed counter 1 (phase Z/reset) High-speed counter 1 (reset) 0.06 High-speed counter 5 - -